Continuous Emission Monitoring System (CEMS) Continuous Emission Monitoring System (CEMS)
Continuous Emission Monitoring System (CEMS)
Continuous Emission Monitoring System (CEMS)

Continuous Emission Monitoring System (CEMS)

155500.00 - 450500.00 INR/Pack

Product Details:

X

Continuous Emission Monitoring System (CEMS) Price And Quantity

  • 1 Pack
  • 155500.00 - 450500.00 INR/Pack

Continuous Emission Monitoring System (CEMS) Product Specifications

  • 5 Kilograms (kg)

Continuous Emission Monitoring System (CEMS) Trade Information

  • 40 Pack Per Week
  • 2-3 Week
  • Within a certain price range free samples are available
  • Normal Packing With Thermocol
  • All India
  • TUV India

Product Description

Continuous Emission Monitoring System Model ATS-208A

Capitalizing rich domain experience, we are able to manufacture, export and supply an excellent quality Continuous Emissions Monitoring System. This analyzer is widely used to determining the level of flue gas to provide information for combustion control in industries. Provided analyzer is manufactured with utmost perfection by utilizing high grade components in complete compliance with defined international norms under the proper supervision of our deft professionals. Moreover, this Continuous Emission Monitoring System can be easily purchased from us at reasonable prices. Also online connectivity with Central Pollution Control Board (CPCB) and State Pollution Control Board (SPCB)

Features:

  • Sturdy construction
  • Excellent functionality
  • Hassle-free performance
  • Less maintenance

Description :

Model ATS-208A continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.

Special gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.

The Sensor and Electronic component are housed in tough aluminium housing.

Specification :

Principle

Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic

Range

%V/V, % LEL, PPM, Mg/M3

Resolution

0.1 Unit or 1 Unit (Application based)

Sampling Method

Auto Suction

Gas Sampling Probe

Dia 8mm SS 316

Display

320 X 264 Graphic LCD

Alarm

Relay Contact NO+NC

Anolog Out Put

4-20mA

Digital Out Put

RS 232, RS 485 and Modbus Comminication Protocol

Power Source

230VAC

Accuracy

+/2%

Response Time

<5 Second

Data Storage

5000 or 10000

Computer Interface

RS 232, USB, RS485

Sensor Life

2-3 Years

Environmental


Temperature

15degree Celsius

Humidity

< 85%RH

Atmosphere Pressure

86- 106Kpa

Dimension in mm

430 (W) X 150(H) X 250(D)

Weight

2.5 KG

Warranty

One Year