TRACE OXYGEN GAS ANALYZER TRACE OXYGEN GAS ANALYZER TRACE OXYGEN GAS ANALYZER
TRACE OXYGEN GAS ANALYZER
TRACE OXYGEN GAS ANALYZER TRACE OXYGEN GAS ANALYZER

TRACE OXYGEN GAS ANALYZER

425000 INR/Number

Product Details:

X

TRACE OXYGEN GAS ANALYZER Price And Quantity

  • 425000 INR/Number
  • 510000.00 - 1.00 INR/Number
  • 1 Number

Product Description

Measurement Parameters

  • Oxygen Range: 0.1 ppm to 25% (depending on application requirements)
  • Resolution: Down to 0.01 ppm for high-precision applications
  • Accuracy: ±1-2% of reading or ±0.1 ppm, whichever is greater
  • Response Time: 10-30 seconds to reach 90% of final reading

2. Sensor Type

  • Electrochemical Sensor: Common for low-ppm detection
  • Zirconium Oxide Sensor: Used for wide dynamic range and high-temperature tolerance
  • Laser-Based Technology (TDLAS): For rapid, interference-free measurement (optional in some high-precision models)

3. Physical and Environmental Specifications

  • Operating Temperature: Typically 0C to 45C (some models support higher ranges)
  • Storage Temperature: -20C to 60C
  • Relative Humidity: 0-95% RH, non-condensing
  • Pressure Range: Often operates up to ±1 bar (some models can handle high-pressure applications)

4. Display and Interface

  • Display: LCD or touchscreen with backlighting for easy reading
  • Data Logging: Stores up to thousands of measurement points; may support external storage (e.g., SD card)
  • Output Signals: 4-20 mA analog output, MODBUS, RS-232/485 digital output
  • Alarms: Adjustable high/low alarm setpoints with visual and audio notifications

5. Power and Battery

  • Power Supply: 100-240 VAC or 24 VDC options
  • Battery Backup: Available in portable models, typically up to 8-10 hours

6. Calibration and Maintenance

  • Calibration: Typically factory-calibrated, with periodic calibration recommended (intervals vary based on model)
  • Calibration Gas: Requires certified trace oxygen calibration gases (0.1-10 ppm O in N or other mixtures)
  • Maintenance: Minimal, with annual or biannual sensor checks or replacement for electrochemical sensors

7. Certification and Compliance

  • Compliance Standards: ISO, ASTM, or specific industry standards for trace oxygen measurement
  • Safety Ratings: ATEX, IECEx, or other certifications for operation in hazardous environments (optional)
  • Environmental Standards: Designed to meet regulatory requirements for industries like pharmaceutical, petrochemical, and semiconductor

These specifications cover the basics, though specific models can vary depending on application needs, sensitivity, and environmental conditions.

Enter Buying Requirement Details